DMCorporativewww.bidapro.net
decrease font increase font

CM WALL PENSTOCK

CM WALL PENSTOCK

Sealed on all 4 sides to be wall-mounted in order to control the flow.

Mainly used for the following applications in:

  • wastewater treatment plants
     
  • drain manifolds
     
  • urban small chest
     
  • storm tanks
     
  • desalination installations
     
  • irrigation installations or any other type of hydraulic work where the flow has to be controlled.
 

 

 


 

General characteristics

Fabricated square or rectangular port wall penstock sealed on all 4 sides, modulate design so that the frame can be used for on-off. Available in different construction materials, with elastic profile sealing and a guided system by means of sliders to reduce rate of friction.

Standard manufacture dimensions from 200 x 200 up to 2000 x 2000 mm. Other dimensions upon request.



 

 

 

 

CONSTRUCTION MATERIALS        
Frame Gate Seal Spindle Extensions Sliders Guide support
304 Aisi Stainless Steel 304 Aisi Stainless Steel EPDM 303 Aisi 304 Aisi Polyethylene 304 Aisi
316 Aisi Stainless Steel 316 Aisi Stainless Steel EPDM 303 Aisi 316 Aisi Polyethylene 316 Aisi
ST37 Carbon Steel ST37 Carbon Steel EPDM 303Aisi 304 Aisi Polyethylene 304 Aisi

Other materials such as DUPLEX, AISI 904L and so on can be manufactured on request.

 

ACTUATOR
Manuals Automatics  
RISING SPINDLE HANDWHEEL ELECTRIC SERVOMOTOR  
NON-RISING SPINDLE HANDWHEEL PNEUMATIC CYLINDER  
RISING SPINDLE REDUCER HYDRAULIC CYLINDER  
NON-RISING SPINDLE REDUCER    

Actuators can be placed directly either on upper frame or with extension systems and column at specified heights.

Other types of actuators upon request.

 

WORKING CONDITIONS
Sizes Immerged side assembly Dry side
assembly
200-1200 10 mWc 5 mWc
1300-2000 5 mWc 0 mWc

OTHER PRESSURES OR BIDIRECTIONAL FLUID APPLICATIONS UPON REQUEST.

 

TIGHTNESS TOLERANCE

According to the American and European Standards.
AWWAC561-04 - 1.24 l/min per seal linear meter.
Din 19569-4 Class 5 - 0.02 l/sec. per seal linear meter.

 

RISING SPINDLE TYPE   NON-RISING SPINDLE TYPE
  • Outside spindle is not in contact with the fluid.
  • Standard open frame
  • Optional closed frame
 
  • Outside spindle in contact with the fluid of the process.
  • Closed frame design.
  • Actuator by means of square device mounted on upper bridge.

 
Compuerta mural CM CM wall penstock
Compuerta mural CM


    Attached archives:
 